CMP1000 AC/DC current measurement (TRUE RMS) up to 1000A. Measurement of INRUSH current in start-up phase of electrical device (high frequency of CMP1000
详情介绍:
AC/DC current measurement (TRUE RMS) up to 1000A.
Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)
AC/DC voltage measurement (TRUE RMS) up to 600V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 40.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
- safe, insulated measuring clamps,
- autoranging/manual range selection,
- DATA HOLD function, for holding measured values,
- backlit LCD,
- DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
- MAX/MIN function,
- over range indication,
- AUTO-OFF function.
CMP-1006 Technical Specifications
Electric security:
measurement category: CAT III 600V acc. to EN 61010-1:2004
protection class acc. to EN 60529: IP40
Other technical data:
power supply: 9V battery type 6LR61
display: 6600 counts, backlit LCD
continuity test: threshold 40Ω; test current < 0,5mA
diode test: test current of 0,3mA, typical open circuit voltage < 3V DC, typical
low battery indication: BAT displayed
over range indication: 0L displayed
sampling rate: 2 times per second
INRUSH: integration time 100ms
temperature sensor: type K thermocouple
input impedance: 10MΩ (V DC and V AC)
AC bandwidth: 50...400Hz (A AC and V AC)
auto power OFF: approx. 25 min.
dimensions: 229 x 80 x 49 mm
weight: 303 g
accordance with following standards: EN 61010-1:2004, EN 61010-2-032
quality standard: ISO 9001
Rated operational conditions:
internal clamp diameters: d1=36mm/d2=52mm
operating temperature: +5...+40°C
storage temperature: -20...+60°C
operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
storage humidity: <80%
operating altitude: max 2000 m
AC/DC current measurement (TRUE RMS)
Range
Resolution
Accuracy
(DC)
Accuracy
(AC)
0...659,9A
0,1A
±(2,5% m.v. +5 dgt)
±(2,5% m.v + 8 dgt)
for f=50...60Hz
660...1000A
1A
±(2,8% m.v. +8 dgt)
±(2,8% m.v. + 8 dgt)
for f=50...60Hz
DC voltage measurement
Range
Resolution
Accuracy
0...6,599V
0,001V
±(1,5% m.v. + 3 dgt)
6,60...65,99V
0,01V
66,0...1000,0V
0,1V
AC voltage measurement (TRUE RMS)
Range
Resolution
Accuracy
0...6,599V
0,001V
±(1,8% m.v. + 5 dgt)
for f=50...60Hz
6,60...65,99V
0,01V
66,0...1000,0V
0,1V
Resistance measurement
Range
Resolution
Accuracy
0,0...659,9Ω
0,1Ω
±(1,0% m.v. + 4 dgt)
0,660...6,599kΩ
0,001kΩ
±(1,5% m.v. + 2 dgt)
6,60...65,99kΩ
0,01kΩ
66,0...659,9kΩ
0,1kΩ
0,660...6,599MΩ
0,001MΩ
±(2,5% m.v. + 3 dgt)
6,60...66,00MΩ
0,01MΩ
±(3,5% m.v. + 5 dgt)
Frequency measurement
Range
Resolution
Accuracy
30,0...999,9Hz
0,1Hz
±(1.2% m.v. + 2 dgt)
sensitivity:30...5kHz:10Vrms min.
5kHz...15kHz:40Vrms min.
for 20%...80% duty cycle