珠海康宝莱仪表有限公司
产品目录
联系我们
产品详情
简单介绍:
Meriam’s M200-DI handheld Smart Manometer for liquids brings high accuracy to wet/wet differential pressure applications. Potentially corrosive or wet gasses are also handled by the M200-DI. Wetted pa
详情介绍:
Wet/Wet Differential Pressure Smart Manometer
M200-DI
Meriam’s M200-DI handheld Smart Manometer for liquids brings high accuracy to wet/wet differential pressure applications. Potentially corrosive or wet gasses are also handled by the M200-DI. Wetted parts are 316L SS with Viton O-rings (consult factory for other materials). The M200-DI features NIST traceable accuracy of ±0.05% FS
(±0.025% FS optional) independent of temperature effect from 23º to 122ºF for Intrinsically Safe models. The accuracy statement is good from -4º to 122ºF for general purpose models.
Pressure ranges are available from 0 - 1 PSID to 0 - 500 PSID. All ranges are rated for 1000 PSI common mode pressure. HI side overpressure rating is 3X F.S. while the LO side overpressure rating is 3X F.S. or 150 PSI, whichever is less. Optional flushing ports (pending) allow solvent clean-out of P1 and P2 ports or can be used to vent air from the connecting tubing of liquid applications.
The display can read in any of 11 pressure units or can be linearly scaled for special user units. A square root flow function allows the M200-DI to display flow in user defined engineer units. The user selectable damping feature minimizes pulsation effects. The Min/Max function captures the extremes of pulsating pressure signals and the
Hold function freezes the display for convenient reading if needed. Auto Record documents up to 240 reading for future recall.
Smart Manometer M200-DI Advantages
Accuracy
± 0.05% FS or optional
± 0.025% F.S. No temperature effect over
specified operating temperature
Certifications
CE compliant
Optional Intrinsically Safe per ATEX and cULus
Engineering Units
Inches of H2O (select 4ºC, 20ºC, or 60ºF), PSI, mm of Hg, inches of Hg, mBars, Bars, kPa, kg/cm2, cm
of H2O, user selectable scaling, sq. root.
Media Compatibility
DI: Isolated differential sensor for fluids compatible with 316L SS and Viton.
Pressure Limits
Common mode:
1,000 PSI
P1 (HI) only: 3X F.S.
P2 (LO) only: 3X F.S. or 150 PSI, whichever is less
Leak Test
Allows users to view Min/Max pressure values and calculates leak rate per minute in pressure units. The feature is very handy when troubleshooting or pressure testing pneumatic systems.
Auto Record
Document up to 240 readings (automatically or manually) to reduce paperwork and field time. Saved readings can be recalled at any time.
Min/Max Capture
Capture speed is equal to the selected damping rate.
Damping Rates
Exponential damping with user selectable time constant from 0.1 to 25 seconds.
Field Re-cal
The M200-DI series can be recalibrated in the field for zero, span, and linearity. The user has the option to select a 1 point or 5 point calibration procedure. Enables users with accurate primary standards to calibrate unit locally if desired.
Auto Shut-Off
User selectable shut-off. Programmable at 10, 20, 30, 45, 60 minutes.
Ordering Information
Model Numbers and Descriptions
- M200-DI (Specify Range)
- Specify accuracy level
- Specify General Purpose or Intrinsically Safe
All Models Include:
- Protective Red Boot
- 4 AA Alkaline batteries
- User’s manual
Order Options
- Intrinsic Safety Certification
- Flushing ports (pending)
- ±0.025% of F.S. or ±0.05% F.S.
Optional Accessories
- Z9A000069 Hard Carrying Case
- Z1066-11 M10-KT Hydraulic scissor pump, 0-10,000 PSIG includes hoses, fittings &carry bag
- Z1089 3-valve manifold assembly,316 SS
(±0.025% FS optional) independent of temperature effect from 23º to 122ºF for Intrinsically Safe models. The accuracy statement is good from -4º to 122ºF for general purpose models.
Pressure ranges are available from 0 - 1 PSID to 0 - 500 PSID. All ranges are rated for 1000 PSI common mode pressure. HI side overpressure rating is 3X F.S. while the LO side overpressure rating is 3X F.S. or 150 PSI, whichever is less. Optional flushing ports (pending) allow solvent clean-out of P1 and P2 ports or can be used to vent air from the connecting tubing of liquid applications.
The display can read in any of 11 pressure units or can be linearly scaled for special user units. A square root flow function allows the M200-DI to display flow in user defined engineer units. The user selectable damping feature minimizes pulsation effects. The Min/Max function captures the extremes of pulsating pressure signals and the
Hold function freezes the display for convenient reading if needed. Auto Record documents up to 240 reading for future recall.
Smart Manometer M200-DI Advantages
Accuracy± 0.05% FS or optional
± 0.025% F.S. No temperature effect over
specified operating temperature
Certifications
CE compliant
Optional Intrinsically Safe per ATEX and cULus
Engineering Units
Inches of H2O (select 4ºC, 20ºC, or 60ºF), PSI, mm of Hg, inches of Hg, mBars, Bars, kPa, kg/cm2, cm
of H2O, user selectable scaling, sq. root.
Media Compatibility
DI: Isolated differential sensor for fluids compatible with 316L SS and Viton.
Pressure Limits
Common mode:
1,000 PSI
P1 (HI) only: 3X F.S.
P2 (LO) only: 3X F.S. or 150 PSI, whichever is less
Leak Test
Allows users to view Min/Max pressure values and calculates leak rate per minute in pressure units. The feature is very handy when troubleshooting or pressure testing pneumatic systems.
Auto Record
Document up to 240 readings (automatically or manually) to reduce paperwork and field time. Saved readings can be recalled at any time.
Min/Max Capture
Capture speed is equal to the selected damping rate.
Damping Rates
Exponential damping with user selectable time constant from 0.1 to 25 seconds.
Field Re-cal
The M200-DI series can be recalibrated in the field for zero, span, and linearity. The user has the option to select a 1 point or 5 point calibration procedure. Enables users with accurate primary standards to calibrate unit locally if desired.
Auto Shut-Off
User selectable shut-off. Programmable at 10, 20, 30, 45, 60 minutes.
Ordering Information
Model Numbers and Descriptions- M200-DI (Specify Range)
- Specify accuracy level
- Specify General Purpose or Intrinsically Safe
- Protective Red Boot
- 4 AA Alkaline batteries
- User’s manual
- Intrinsic Safety Certification
- Flushing ports (pending)
- ±0.025% of F.S. or ±0.05% F.S.
- Z9A000069 Hard Carrying Case
- Z1066-11 M10-KT Hydraulic scissor pump, 0-10,000 PSIG includes hoses, fittings &carry bag
- Z1089 3-valve manifold assembly,316 SS