产品详情
  • 产品名称:AT2327报警剂量计辐射监测系统(地铁车辆用)

  • 产品型号:AT2327
  • 产品厂商:阿通特斯ATOMTEX
  • 产品价格:0
  • 折扣价格:0
  • 产品文档:
你添加了1件商品 查看购物车
简单介绍:
AT2327为一自动的静态装置,在现场提供连续的辐射监测。 操作原理以伽马辐射智慧型探针BDKG-11/1和/或BDKG-11/2(SP)为基础,*多可装置10支智慧型探針。 当超过预计的计数率的门欯时,便由声音和视觉警报单元(AU)警告人员侦测到伽马源。 量测期间所测得的计数率数据,由每一探针经由RS385传送到远端控制室的处理单元(PU)。 BDKG-11/1在137Cs敏感度1960 cp
详情介绍:
VEHICLE RADIATION MONITOR WITH USING OF ALARM DOSIMETER AT2327
 

 Automatic stationary radiation monitoring device based on АТ2327 alarm dosimeter designed for detection of gamma radiation sources in transportation vehicles crossing check points.



Features

- Up to 10 highly sensitive smart probes in hermetic aluminum containers, simultaneously measuring intensity of gamma radiation  
- Audible and visual alarm at threshold exceeding  
- Automatic switch from background measuring mode to detection mode when photoelectric detector infrared beam is interrupted by transportation vehicle  
- Radiation monitoring of transportation vehicles in motion  
- Self control of components during operation  
- Extreme environment operation  
- Database of counting rate values and alarm threshold excesses  
- Reserve power supply - up to 6 hours of continuous operation with a fully charged battery  


Application

- Metallurgy industry
- Waste handling
- Cargo entrances in ports and railroad stations
- Nuclear industry


Automatic stationary device for continuous radiation monitoring is designed as stationary equipment mounted on site based on АТ2327 alarm dosimeter. The alarm dosimeter principle of operation is based on gamma radiation smart probes BDKG-11/1 and/or BDKG-11/2 (SP), maximum quantity – 10 smart probes. When a transportation vehicle crosses area under monitoring, it interrupts infrared beam that passes from IR radiator to IR receiver of photoelectric detector, in this case all smart probes automatically switch from rated background measuring mode to detection mode. When preset threshold of counting rate is exceeded, the audible and visual alarm (AU) warns personnel about detection of a gamma source. During measurement, counting rate information is transferred from each smart probe to processing unit (PU) located remotely in control room, via RS485.

The processing unit displays measured values of the selected smart probe and real time. Alarm threshold exceeding or a failure of any system units is accompanied by audible and visual signals showing symbolically the problem location on the display. The processing unit is intended to setup thresholds for each smart probe, monitor smart probe state, correct the real-time clock, protect several service functions with a password and review counting rate and threshold exceeding history of any smart probe.

Specification
 
Number of smart probes up to 10
Detector
BDKG-11/1
NaI(TI) ø63х63mm
BDKG-11/2 NaI(TI) ø63х160mm
Sensitivity, not less than
on 241Am
BDKG-11/1 12700 cps/mSv•h-1
BDKG-11/2 30000 cps/mSv•h-1
on 137Cs
BDKG-11/1 1960 cps/mSv•h-1
BDKG-11/2 4900 cps/mSv•h-1
on 60Co
BDKG-11/1 1030 cps/mSv•h-1
BDKG-11/2 2500 cps/mSv•h-1
radiation background 0.08 μSv/h
BDKG-11/1 150 cps
BDKG-11/2 370 cps
Sensitivity, on 137Cs, point source located to “+” mark on hermetic container
BDKG-11/1 60,8 ± 12,1 cps/kBq
BDKG-11/2 120 ± 24 cps/kBq
Maximum input statistical
load BDKG-11/1, BDKG-11/2
at least 5•104 s-1
Gamma radiation energy range 0,05 - 3 MeV
Instability of measuring results during
continuous operation
not more than 5%
Continuous operation time
AC supply
at least 24 hours
with fully
charged battery
at least 6 hours
Maximum vehicle speed during measurement 5 kmh
Monitoring time
per vehicle
max 20 s
Operating temperature range
Processing unit
+5 - +40 °С
other components and BDKG-11/1 -30 - +50 °С
BDKG-11/2 -15 - +40 °С
3-level visual and audible alarm
Operation mode
setup time
not more than 5 min
Interface (cable communication) RS485
Maximum width of checkpoint 5000 mm
Maximum distance
between a smart probe and the processing unit (cable communication)
1000 m
Protection class
smart probes
IP57
other components IP50
Radio disturbance
CEI/IEC CISPR 22:1997
Electromagnetic compatibility
CEI/IEC 61000-4-2:1995,
IEC 61000-4-3:1995
Power supply
AC mains 220 (+22;-33) V; frequency 50 (±2) Hz and accumulator battery at emergency 12,6 (+1,3;-1,6) V or 25,2 (+2,6;-3,2) V




Complete set: processing unit, smart probes BDKG-11/1 and/or BDKG-11/2 in hermetic containers, alarm units, photoelectronic detector, terminal-block boxes, AC adapter, interface adapter, Manual, complete of assembly parts and accessories.

Backup power unit on additional order.
 

Alarm dosimeter AT2327 has pattern approval certificates of Republic of Belarus, Russian Federation, Ukraine and Kazakhstan.

It complies with IEC 61017-7 International standard requirements. They also conform with the 89/336/EEC directive complying with EN 61000-6-3, EN 61000-6-2, EN50371, EN61010-1 standard requirements.