Description: Multi-Channel Controller Analog Inputs: Four; 4-20 mA Pulse Inputs: Four; 100 mVp-p to 15 Vp-p; 1 Hz to 10 kHz Display: 4.75" x 3.50" (121 mm x 89 mm) Backlit LCD; 6-Digit Case: NEMA 1, P
详情介绍:
ConsoliDator-Logo

Model PD940 ConsoliDator® 4

Model PD981 ConsoliDator® 8


PD940 ConsoliDator 4 and 8 Multi-Channel Controller

ConsoliDator 4 Features


  • Four 4-20 mA Inputs
     
  • Four 4-20 mA Outputs

PD940 ConsoliDator 4 and 8 Multi-Channel Controller

ConsoliDator 8 Features


  • Eight 4-20 mA Inputs
  • Two 4-20 mA Outputs
I'd like to make an inquiry on these products

 
 

COMMON FEATURES

  • Four Pulse Inputs
     
  • Four Digital Inputs
     
  • Nine 10 A Relays
     
  • Process/Rate & Total Display
 

ADVANTAGES

  • Easy to Read Backlit LCD
     
  • Readable in Direct Sunlight
     
  • Bargraphs & Numeric Screens
     
  • Easy to Set up & Configure
     
  • Set up with Front Panel Keys
     
  • Intuitive Menus
     
  • Detailed Individual Screens
     
  • Input Simulation Feature
     
  • RS-232 Modbus® RTU
     
  • Direct Modbus PV Inputs
     
  • Power from AC or DC
     
  • Wall or Panel Mount
     
  • 32-Point Linearization
     
  • Sum & Difference Functions
     
  • Free Programming & Data Logging Software
     
  • A Good Match for Wireless
 

CONFIGURATION


PD940 and PD981 ConsoliDator 4 and 8 Multi-Channel Controllers Main Setup Menu Screen


  • No ladder logic programming

     
  • Front Panel Soft Keys
     


  • PC-based software for configuration

     
  • Full-word prompts


The number one thing our customers like about the ConsoliDator is that it is easy to configure and use. Any other similar display would require complicated programming and still not have a user interface that is this friendly. The full-word prompts and graphical layout are so intuitive, you may have little use for the manual. While configuring the inputs, outputs, and functions the “soft” keys appropriately and clearly relabel the action of the front panel buttons making menu navigation quick and simple. Each configuration screen presents a clear non-cryptic summary of settable parameters and their current values.


 

ConsoliDator program analog input.jpg

ConsoliDator alarm
 
Color shown for illustration only


 
 

OPERATION

PD940 and PD981 ConsoliDator 4 and 8 Multi-Channel Controllers Operation Master Input Screen

 
  • Bargraphs and Numeric Data

     
  • Main Screen Shows all Inputs

     
  • Individual Screens Show Detailed Data
 


The ConsoliDator has an excellent graphical display and interface, presenting a quick view of the process while providing clearly and logically labeled operating keys. The main operation screen has a large bargraph display to quickly help spot trends or problems. It also indicates the precise numeric values for each PV input. Custom tag names and units of measure make the data more familiar, thus easier to read and understand. In addition to the three operation screens shown below, there are screens showing Digital Input States, Flow Meter Input Values, as well as a detailed numeric screens for each input. Cycle through all these screens with a push of a button. The ConsoliDator offers advanced operations without all the programming required by a PLC.


 
manual mode screen

Key Points Shown

  • View relay status
    On and off status
    Hours of operation
    Operation cycles

     
  • Control relay operation
    Reset hours and cycles
    Toggle status on and off
individual screens

Key Points Shown

  • Bargraph with set points

     
  • Input Identification

     
  • Engineering Units label (gal, ft, GPM)

     
  • Alarm status
    Assigned alarms 1 and 3
    Low and high set points
    On and off status

     
  • Input simulation
    Test setup without applying an input
Color shown for illustration only


 

MODBUS SERIAL COMMUNICATIONS

Modbus RTU

Use the Consolidator’s Modbus RTU communications (standard) to connect the Consolidator to a PLC, SCADA system or other digital device. An RS-232 port is standard on the Consolidator. A Null Modem cable (PDA9232-01) is required when connecting to another DTE device such as a computer. When connecting to a modem (including wireless modem) or other DCE devices, a standard RS-232 cable (PDA9232-02) would be required. Connecting to a computer’s USB port would require both a Null Modem cable (PDA9232-01) and a USB to RS-232 Converter cable (PDA8232-N).

Communication Adapters, Converters, and Cables

Adapters and Converters

A wide variety of serial communication adapters and converters are available for the ConsoliDator. A serial adapter and Precision Digital’s free ConsoliDator software allows the it to be configured from a computer and to connect to a PC for data acquisition. Adapters are available for RS-232 and RS-422/485 communications. Converters are available for isolated and non-isolated RS-232 to RS-422/485 and USB to RS-422/485.


MODBUS SERIAL PV INPUTS

The ConsoliDator’s inputs can be a combination of analog inputs and Modbus PV inputs which use the ConsoliDator’s built-in RS-232 serial port. For the Modbus inputs, simply configure the input(s) to “Fixed” mode, then write the PV value to the appropriate Modbus register. The ConsoliDator must be the slave end of the communications. A pair of radio modems could make the communications wireless!


Consolidator with Modbus Applications


 

CONSOLIDATOR SOFTWARE

Free PC based software is included with every ConsoliDator. With this software the user can monitor process variables, relay states, alarm states, and switch input states. The software can be used as a data logger, or to configure the ConsoliDator.

Main Display

PD940 and PD981 ConsoliDator 4 and 8 Multi-channel Controllers Wall Mount Overall Dimensions
On the main display screen of the software, the bargraph display not only shows the current PV value, it also shows any set and reset alarm points (gray lines on bargraph). On this screen you can also monitor relay and switch input states.


Recent History Viewer

PD940 and PD981 ConsoliDator 4 and 8 Multi-channel Controllers Wall Mount Overall Dimensions
When an input channel is selected on the main display screen, a graph of recent history (last 5-10 minutes) can be viewed. A bargraph of its current value is also present.


Data Logging

PD940 and PD981 ConsoliDator 4 and 8 Multi-channel Controllers Wall Mount Overall Dimensions

The data logger allows you to log the PVs over time. A CSV file is created so that the data can be used by a spreadsheet program. Log rate intervals can be set from 1 second to 10 minutes.


Configuration

PD940 and PD981 ConsoliDator 4 and 8 Multi-channel Controllers Wall Mount Overall Dimensions

The ConsoliDator can be remotely configured with this software by inputting the configuration data directly, or by copying a configuration from another ConsoliDator. Configurations can also be saved to your computer for future use.

 

WIRELESS APPLICATIONS

Remote Level Sensing

 
Remote Monitoring

 
wireless tank sensing wireless retransmission
Here is an application where the level of 8 tanks are wirelessly monitored at practical and convenient locations without the need for expensive hard-wiring. The NEMA 4X enclosure contains wireless devices that convert the 4-20 mA level signals from the level transmitters into a digital signal that is wirelessly sent to a ConsoliDator (below).

 
These four Trident displays receive retransmitted signals
wirelessly from a remote ConsoliDator. They can be
mounted from hundreds to thousands of feet away from the ConsoliDator depending upon the level of signal interference. Repeaters can be used to extend the range of wireless operation.

 
Local Display of Tank Level Data

 
Remote Office Connection to ConsoliDator

 
wireless local display wireless serial communication
This wireless ConsoliDator receives up to eight channels of process data and displays it in a practical location for easy monitoring. This same information can be wirelessly retransmitted via wireless serial Modbus to the office (at right), or up to (4) 4-20 mA retransmitted signals can be sent wirelessly to meters at a remote site (upper right) and displayed on any 4-20 mA input device (meter, recorder, data logger, etc.). Using the RS-232 Modbus serial output on the ConsoliDator, data can be analyzed and/or data logged remotely on a PC by utilizing a set of wireless radio modems and the free PC based software included with the ConsoliDator. The ConsoliDator can also be remotely configured using this software. Configuration files can be uploaded or downloaded to the PC and stored in the form of a spreadsheet.


Click here for more information on Wireless ConsoliDator

 

 

FIELD ENCLOSURES

Consolidator_PDA2901
PDA2901

  • NEMA 4X
     
  • Hinged clear cover
     
  • Stainless steel quick-release latches
     
  • Easy access to front panel buttons
     
  • Power switch & fuse

Consolidator_PDA2901_open
Shown with
Optional Sub-Panel

  • Hinged front mounting panel
     
  • Extra space for additional components
     
  • PDP2901 panel with terminal strips
     
  • Captive screws


For more information on the PDA2901, click here


 
 

CONNECTORS DIAGRAM



Consolidator Silkscreen


The connectors diagram is silk-screened on the back of all panel mount ConsoliDators (PD941 shown here).



Wall Mount

 

Overall Dimensions Mounting Dimensions
Units: Inches (mm)
ConsoliDator overall Wall ConsoliDator mounting Wall


Panel Mount

 

ConsoliDator overall Panel ConsoliDator mounting Panel


Enclosures

 

Consolidator PDA2901 mounting dimension Consolidator PDA2904 mounting dimension
For more information on the PDA2901, click here
 

SPECIFICATIONS

Except where noted all specifications apply to operation at +25°C.

General

Display: Backlit LCD; 4.75˝ x 3.50˝ (121 mm x 89 mm)
Display Update Rate: 2 seconds
Programming Method: Front panel buttons, external buttons, PC with ConsoliDator software, or Modbus registers.
Password: Programmable, restricts modification of settings.
Non-Volatile Memory: Settings stored for a minimum of 10 years.
Power: 90-264 VAC, 47-63 Hz, 20 VA or 8-30 VDC, 15 W (field)
Isolation: AC: 1500 V; signal and output power grounds are connected to earth ground (chassis); DC: not isolated.
Surge Protection: Analog inputs have chokes & TVS
Operating Temperature: 0 to 50°C
Relative Humidity: 0 to 90% non-condensing
Storage Temperature: -40 to 60°C
Connections: Removable screw terminals and DB9 male
Enclosure: NEMA 1, powder-coated steel; color: warm gray
Mounting: Panel or wall mount models
Weight: 5.5 lb (2.5 kg)
UL File Number: E160849; 508 Industrial Control Equipment
Warranty: 1 year parts & labor

Screen Displays

Numeric Display: Six digits, ±999999 or 99' 11.9" (feet & inches)
Bargraph: Twenty divisions
Engineering Units: User selectable or definable units (e.g. ppm, gal, m, lb, g/h, psi, ozs, ft, mA, ºC, ºF, f & i, %)
Master Input Screen:
    Numeric Displays: Eight; process value & engineering units
    Bargraphs: Eight; process & channel number
Individual Input Screen:
    Numeric Displays: Process and mA input value
    Bargraphs: High and low set point markings
    Simulation Mode: Test setup without applying an input

Analog Inputs

Number of Inputs: Four (ConsoliDator 4); Eight (ConsoliDator 8)
Input: 4-20 mA; minimum span of 1 mA
Accuracy: ±0.03% FS ±1 count
Input Function: Linear, square root, programmable exponent, or fixed value
Programmable Exponent: From 0.50001 to 2.99999
Multi-Point Linearization: 2 to 32 points, accessible through ConsoliDator software or Modbus registers.
Math Function: Sum or difference of 2 or more channels
Totalizer: Calculates total based on rate and time base of seconds, minutes, hours, or days; stored in non-volatile memory every 5 minutes; supports linear inputs only.
Totalizer Reset: Via front panel buttons (password restricted)
Input Impedance: 130 Ω
Transmitter Supply: 24 VDC @ 20 mA per input; short circuit protection: current limited to 40 mA max per input

Pulse Inputs

Number of Inputs: Four
Input: 100 mVp-p to 15 Vp-p; 1 Hz to 10 kHz
Accuracy: ±1 count for K-Factor >1
K-Factor: 0.00001 to 999999 pulses/unit
Totalizer: Calculates total based on rate, stored in non-volatile memory every 5 minutes.
Totalizer Reset: Via front panel buttons (password restricted)

Digital Inputs

Number: Four
Type: Switch closure, open collector transistor, or logic level
Input Impedance: 240 Ω

Modbus PV Inputs

Number: Up to 4 (ConsoliDator 4), and up to 8 (ConsoliDator 8)
Input: Modbus via RS-232 serial port

Relays

Number of Relays: Nine
Relay Type: Form C (SPDT) with built in MOVs
Rating: 10 A @ 120/240 VAC resistive load; 1/3 HP @ 120/240 VAC inductive loads; 5 A @ 28 VDC
Minimum Load: 50 mA for AC, 10 mA @ 5 VDC
Assignment: Any relay may be assigned to any channel. Multiple relays may be assigned to one channel. All relays are programmed independently.
Cycle Monitoring: Controller tracks time relay has been active and number of times relay has cycled on/off.
Time Delay: Programmable on/off delays, 0 to 999.9 seconds
Operation: (see instruction manual for complete list) High or Low Alarm, Multi-Channel Alarm, Summary Alarm, Supervisory Alarm, and Lead-Lag Alternation (Sequence)
Manual Override: Override any relay (password restricted). Relays do not respond to input while in this mode.

4-20 mA Analog Output

Number: Four (ConsoliDator 4); Two (ConsoliDator 8) Assign to any process or pulse input
Accuracy: ±0.05% FS ±0.01 mA
Mode: Linear or manual tuning PID
Loop Resistance: 10 to 600 Ω, powered by controller
External Loop Power Supply: 12 VDC min (300 Ω max); 32 VDC max (900 Ω max)
Isolation: 1500 V output-to-power line; 500 V output-to-input when powered by external supply.

Modbus Communications

Compatibility: EIA-232
Protocol: Modbus RTU
Address: Programmable between 1 and 247
Baud Rate: 1,200 to 38,400 bps
Transmit Delay: Programmable between 0 and 300 ms
Data: 8 bits (1 start bit, 1 stop bit)
Parity: Even, None with 1 stop bit, or None with 2 stop bits

ConsoliDator Software

System Requirements: Windows® 95/98/ME/NT4/2000/XP
Communications: RS-232 using null-modem serial cable
Compatibility: ConsoliDator 4 & ConsoliDator 8, two versions
Configuration: Configure inputs and outputs. Save settings to file for programming other controllers or restoring settings.
Logging Interval: 1 second to 10 minutes
Data Logging Report: Log to comma separated value(.csv) file compatible with spreadsheet applications

 

ORDERING INFORMATION

Products

Model Description  
PD940-8K9-15        ConsoliDator® 4 Multi-Channel Controller; Four 4-20 mA Inputs, 4 Pulse Inputs, Four 4-20 mA Outputs; Wall Mounted Case         
PD941-8K9-15        ConsoliDator® 4 Multi-Channel Controller; Four 4-20 mA Inputs; 4 Pulse Inputs; Four 4-20 mA Outputs; Panel Mounted Case         
PD980-8K9-15        ConsoliDator® 8 Multi-Channel Controller; Eight 4-20 mA Inputs; Four Pulse Inputs; Two 4-20 mA Outputs; Wall Mounted Case         
PD981-8K9-15        ConsoliDator® 8 Multi-Channel Controller; Eight 4-20 mA Inputs; Four Pulse Inputs; Two 4-20 mA Outputs; Panel Mounted Case         
  

Enclosures
 

Model Description  
PDA2901        NEMA 4X Enclosure for ConsoliDator® models PD941 or PD981         
PDA2904        NEMA 4X Large Enclosure for ConsoliDator® models PD941 or PD981         
  

Accessories

Model Description  
PDP2901        Sub-Panel with Terminal Strips for PDA2901         
PDP2902        Sub-Panel without Terminal Strips for PDA2901         
PDP2904        Sub-Panel with Terminal Strips for PDA2904         
PDP2905        Sub-Panel without Terminal Strips for PDA2904         
PDA6901        2" Pipe Mounting Kit for PDA2901         
PDA6902        2" Pipe Mounting Kit for PDA2904         
PDA7485-I        RS-232 to RS-422/485 Isolated Converter         
PDA7485-N        RS-232 to RS-422/485 Non-Isolated Converter         
PDA8232-N        USB to RS-232 Converter         
PDA8485-I        USB to RS-422/485 Isolated Converter         
PDA8485-N        USB to RS-422/485 Non-Isolated Converter         
PDA9232-01        ConsoliDator Null-Modem Cable         
PDA9232-02        RS-232 Computer Cable         
PDX6901        Suppressor (snubber): 0.01µF/470Ω,