The M1 Series of handheld manometers from Meriam Process Technologies combines form, fit and function to deliver precision pressure measurement for field, plant or lab use. For reference indication an
详情介绍:
Digital Manometer/Calibrator
M1 SeriesThe M1 Series of handheld manometers from Meriam Process Technologies combines form, fit and function to deliver precision pressure measurement for field, plant or lab use. For reference indication and shirt pocket convenience, select the low cost M100 Digital Manometer with its +/- 0.25% FS accuracy. Or specify the
M101 Calibrator when better accuracy is needed for more exacting measurements. The M101 delivers +/- 0.10% FS accuracy and additional features normally found on higher priced instruments. Both models are available in differential, gauge and absolute pressure versions.
Applications
• Leak testing for low pressure gas systems
• Pressure drop monitoring across filters
• Monitoring vacuum on condensers or pumps
• Verification of CPAP or BIPAP systems for home or hospital settings
M1 Series Advantages
Engineering Units (8-selectable)
Inches of H2O @ 20°C, mm of H2O @ 20°C, mm of Hg @ 0°C, Inches of Hg @ 0°C, kPa, mBar, Bar,
PSI and user selectable.
Media Compatibility
Non-isolated sensor for clean, dry, non-corrosive gases.
Pressure Limits
(DN) units - 3 x F.S. on high side only or 200 PSI, whichever is less. (GN or AN) units - 3 x F.S. range or 200 PSI,
whichever is less.
Accuracy
M100: ±0.25% FS
M101: ±0.10% FS
No temperature effect over the entire operating range 14°F to 122°F (-10°C to +50°C).
Min/Max (M101 only)
Displays the MIN and MAX pressures.
Hold (M101 only)
Freezes the pressure measurement on the display, however, the bar graph is still active.
Ave (M101 only)
Displays a continuous filtered average of the pressure measurements.
Temp
Displays the internal ambient temperature of the M1 in °C or °F.
Record Mode
The M1 can store up to 240 pressure measurements.
• Automatic – the current value is automatically stored every 5 seconds, for up to 20 minutes.
• Manual – the current value is stored every time the Units key is pressed, up to 240 times.
Backlight
A green backlight is user activated via the backlight key. A red backlight is automatically activated during an error/over-range condition.
Battery Life
300 hours without backlight
Auto Shutoff
To conserve battery life, the M1 will automatically power off after 20 minutes of keypad inactivity.
Field Recalibration
M1 can be calibrated in the field for zero and span.
Low Battery Indication
BAT icon is displayed when batteries require replacement. Approximately 2 hours of run time is provided on a low battery condition.
Bar Graph
Horizontal bar for full scale pressure reference (0-100%).
Optional Accessories
ZA34386 Calibration Kit, Includes:
Z9P000058 Spare Protective Boot – Red
(each M1 comes standard with a protective boot)
Z1055 NIST Traceable Certificate with Data
M101 Calibrator when better accuracy is needed for more exacting measurements. The M101 delivers +/- 0.10% FS accuracy and additional features normally found on higher priced instruments. Both models are available in differential, gauge and absolute pressure versions.
Applications
• Leak testing for low pressure gas systems
• Pressure drop monitoring across filters
• Monitoring vacuum on condensers or pumps
• Verification of CPAP or BIPAP systems for home or hospital settings
M1 Series Advantages
Engineering Units (8-selectable)
Inches of H2O @ 20°C, mm of H2O @ 20°C, mm of Hg @ 0°C, Inches of Hg @ 0°C, kPa, mBar, Bar,
PSI and user selectable.
Media Compatibility
Non-isolated sensor for clean, dry, non-corrosive gases.
Pressure Limits
(DN) units - 3 x F.S. on high side only or 200 PSI, whichever is less. (GN or AN) units - 3 x F.S. range or 200 PSI,
whichever is less.
Accuracy
M100: ±0.25% FS
M101: ±0.10% FS
No temperature effect over the entire operating range 14°F to 122°F (-10°C to +50°C).
Min/Max (M101 only)
Displays the MIN and MAX pressures.
Hold (M101 only)
Freezes the pressure measurement on the display, however, the bar graph is still active.
Ave (M101 only)
Displays a continuous filtered average of the pressure measurements.
Temp
Displays the internal ambient temperature of the M1 in °C or °F.
Record Mode
The M1 can store up to 240 pressure measurements.
• Automatic – the current value is automatically stored every 5 seconds, for up to 20 minutes.
• Manual – the current value is stored every time the Units key is pressed, up to 240 times.
Backlight
A green backlight is user activated via the backlight key. A red backlight is automatically activated during an error/over-range condition.
Battery Life
300 hours without backlight
Auto Shutoff
To conserve battery life, the M1 will automatically power off after 20 minutes of keypad inactivity.
Field Recalibration
M1 can be calibrated in the field for zero and span.
Low Battery Indication
BAT icon is displayed when batteries require replacement. Approximately 2 hours of run time is provided on a low battery condition.
Bar Graph
Horizontal bar for full scale pressure reference (0-100%).
Ordering Information
Model Number & Description- M100 - (specify pressure range) - Digital Manometer
- M101 - (specify pressure range) - Calibrator
Optional Accessories
ZA34386 Calibration Kit, Includes:
- (3) Nylon tubing, 6 ft., PN: A34103-3,
- (2) Tee, Brass, 1/8” O.D. Tubing PN: A34112,
- (1) Adapter, 3/16” Hose Barb to 1/8” MNPT PN:A34142-2,
- (6) Adapter, 1/8” O.D. Tube to 1/8” MNPT PN: A34012
- Nylon Tubing, 10 FT., PN: A34103-2
- Adapter, Brass, Tubing to 1/8” MNPT PN:A34102
Z9P000058 Spare Protective Boot – Red
(each M1 comes standard with a protective boot)
Z1055 NIST Traceable Certificate with Data