INTRODUCTION
The ProVu meter boasts specifications and functionality that clearly makes it one of the most advanced temperature meters available. Its dual-line 6-character display, function keys, and optional expansion modules are only a few of the special features available on the ProVu.
Versatile
The PD7000 accepts many more thermocouple types and RTDs than earlier models. It can be configured to have either a 1° or 0.1° display resolution on any type of sensor input. The lower display makes configuration simpler. The display itself is quite configurable. There are many relay functions for up to 8 relays; including an Interlock Relay function. The 4-20 mA output can represent up to 12 different parameters/variables. This makes the PD7000 one of the most versatile meters on the market.
FRONT PANEL DISPLAY
Precise, Accurate, and More Informative
ProVu's large 0.6" upper display provides an accurate and precise 4 or 5-digit view of the temperature measurement.
Configurable
The upper display can be programmed to indicate current temperature, maximum or minimum temperature, alternating maximum/minimum temperatures, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off.
Function Keys
There are three function keys available to the user. These keys can be programmed to trigger certain events
( i.e. acknowledge alarms, reset max and/or min, disable/enable output relays, or hold current relay states), provide direct menu access points, and more.
Learn more about using the ProVu's Function Keys by watching a video click here to watch.
Optional SunBright Display Models
ProVu's SunBright display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. There are 8 user selectable intensity levels to choose from on all ProVu models. This option is available on all ProVu models.
Easy to Use
The user friendly dual-line display makes the ProVu easy to set up & program. Input selection and configuration is conveniently set up via rear switches and front panel programming. Three levels of password protection help maintain the reliability of the programming.
Three Tier Password Protection
The ProVu offers 3 levels of password protection:
- Level 1 protection allows the operator use of only the 3 pre-configured function keys on the front panel without a password.
- Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password.
- Level 3 protection restricts the operator from using the function keys and all meter configuration menus without a password.
Rugged
A unique front panel design makes the ProVu nearly impenetrable in typical applications. Here, the ProVu easily survives a direct hit on the display from a heavy 2" solid stainless steel ball dropped from eight feet.Simplified & Dynamic Menu System
The ProVu minimizes the menu selections by auto-detecting the installed options to determine what menu navigation is required. For example, extra menu items for the relay expansion module, I/O expansion, etc. are not present unless those options have been installed. This is an example of keeping the product simply sophisticated.
Max/Min Display
Max/Min (or Peak/Valley) is standard on the ProVu PD7000. Either display can be configured to show either maximum or minimum excursion since last reset. The displays can also be configured to toggle between Max and Min values. Both values can be simply reset from the front panel.
Environmentally Protected
The ProVu has standard UV protection, a NEMA 4X front panel, extremely durable face plate, performs in wide ambient operating temperatures, and is CE Certified (high noise and RF immunity).
DIGITAL COMMUNICATIONS
Modbus® RTU Serial Communications
After the purchase of a serial communication adapter for the ProVu meter, any Modbus-ready Master device can communicate with the meter using the ever-popular Modbus communications protocol included in every ProVu. This greatly increases the flexibility of the meter. Modbus provides much more capability than read PV and write set points. Below are some examples of other things that can be done with ProVu's Modbus communications.
- Send a 6-character message to the lower display upon an event
- Convert a digital value to a 4-20 mA signal
- Remote user control (i.e. change set points, acknowledge alarms)
- Input a Modbus digital PV (in place of analog input)
- Remote override of any, or all, relays and analog outputs
Meter Copy
The Copy feature is used to copy (or clone) all the settings from one ProVu to other ProVu meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adapter, only an optional cable assembly, P/N PDA1200. See the ordering information for complete details.
MULTIPLE SENSOR AVERAGING
The PD7000 can find the average temperature of up to 10 RTD probes connected in parallel. This new calculated value would then be treated as the PV (temperature) displayed on the meter. The average temperature is also available via Modbus communications and as the retransmitted value for the optional 4-20 mA output.
METERVIEW® PRO SOFTWARE
Click here to see the
ProVu videos
ProVu series meter using the PC-based MeterView Pro (MVP) software (serial communications adapter required). MVP makes complete meter configuration simple and fast. Copying one meter configuration to another, as well as saving or retrieving a meter configuration file is a snap. MVP's linearization utility makes even a 32-point linearization task clear and easy to do. We also included a basic meter monitor and data logger for use with a ProVu. Of course, with ProVu's powerful Modbus protocol, custom programs can be made even more versatile. For more details on MeterView Pro, click here.
Monitor and Datalog |
Setup |
Relays |
ProVu VIDEOS
Watch a quick demonstration on how the ProVu works and also how the function keys can simplify functionality. These and other videos are available at here.
FIELD EXPANSION MODULES
Add functionality to the ProVu in the field with easy-to-install external expansion modules. Add RS-232 or RS-422/485 communications, I/O modules (up to 2), and 4-relay expansion module. The menu items for these modules do not appear until the module is connected, simplifying the basic menu. Relay and digital I/O modules are shown below with optional DIN rail mounting kit, P/N PDA1002.
PDA1044 I/O Expansion Module
Four digital inputs and four digital outputs are available per expansion module. The ProVu meter will accept two of these modules. External digital inputs can function similarly to the front panel function keys. They can be configured to trigger certain events (i.e. acknowledge/reset alarms, reset max and/or min values, disable/enable all output relays, and hold current relay states), provide direct menu access point, or mimic front panel keys. The I/O module can be used to configure the ProVu remotely, in essence giving the user control of the four front panel push buttons. This feature is particularly useful if the meter is mounted inside an explosion-proof enclosure.
Digital outputs can be used to remotely monitor ProVu's alarm relay output states, or the states of a variety of actions and functions executed by the meter.
PDA1004 Relay Expansion Module
An external module containing four 3 A Form A (SPST) relays can be added to the ProVu at anytime. Removable screw terminal blocks accept 12 to 22 AWG wire.
PDA1232 & PDA1485 Communication Modules
Serial communications on the ProVu can be added anytime with external PDA1232 (RS-232) or PDA1485 (RS-422/485) communication adapters.
Free Modbus protocol with purchase of ProVu serial communications modules.
OUTPUTS
Relay Outputs
The ProVu has up to four 3 A Form C relays (SPDT) with multiple power loss fail-safe options. Relays can be configured for proper protective action upon input loop break. Relay ON and OFF delay times are user adjustable. Up to eight front panel indicators show alarm and/or relay state. All relays can be configured for 0-100% deadband.
Relay Operation/Configuration
There are powerful relay functions that can be configured in the ProVu meter, including:
- Automatic reset only (non-latching)
- Automatic + manual reset at any time (non-latching)
- Latching (manual reset only)
- Latching with clear (manual reset only after alarm condition has cleared)
- User selectable fail-safe operation
- Relay action upon sensor break
- Time delay (on and off), independent for each relay
- Manual control mode
- Interlock Relay Mode
Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset.
Analog Output
The isolated analog output signal can be configured to represent the measured temperature (including average temperature), maximum or minimum temperature, any of the eight relay set points, manual control setting, or Modbus input. While the output is nominally 4-20 mA, the signal will accurately accommodate under- and over-ranges from 1 to 23 mA. A power supply (24 V @ 40 mA) is standard with the 4-20 mA output option.
Auto/Manual Control
Take control of any output with this feature. All relays can be forced ON or OFF, and the 4-20 mA output signal can be set to any value within its range. When the relays and 4-20 mA output are controlled manually, an LED labeled "M" is turned on and the associated Alarm LEDs (1-8) flash every 10 seconds indicating that the meter is in manual control mode.
Interlock Relay(s)
This function allows a process to use one or more very low voltage input signals or simple switch contacts to control the state of one or more internal "interlock" relays. A violation (i.e. loss of input, open switch, or open circuit) forces one or more N/O interlock relay contacts to open. One input can be used in series with a number of interlock switches, or up to eight inputs can be required to force-on one (or more) internal interlock relays. Please see Application Note AN-1008 for more information.
Note: Requires PDA1044 Digital I/O module.
NEMA 4 & 4X FIELD ENCLOSURESThermoplastic and stainless steel NEMA 4X, and painted steel NEMA 4 enclosures for up to 10 ProVu meters are available. Please visit our Enclosure Selection Utility at www.predig.com/esu for an easy way to find the right enclosure. |
Enter the Enclosure Selection Utility |
CONNECTIONS
|
MOUNTING DIMENSIONS
Notes:
1. Panel cutout required: 1.772" x 3.622" (45mm x 92mm)
2. Panel thickness: 0.040 - 0.250" (1.0mm - 6.4mm)
3. Mounting brackets lock in place for easy mounting
4. Clearance: Allow 6" (152 mm) behind the panel.
SPECIFICATIONS
Except where noted all specifications apply to operation at +25°C.
General
Display: upper display: 0.60" (15 mm) high, lower display: 0.46" (12 mm) high. Both displays are 6-character (-99999 to 999999), red LEDs with leading zero blanking. Temperature value is four or five-digit F/C, based on configuration.
Resolution: 1° (up to four digits) or 0.1° (up to five digits)
Display Intensity: Eight intensity levels
Display Update Rate: 5/second (200 ms)
Front Panel: NEMA 4X, IP65
Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro Software, Modbus registers, or cloning using Copy function.
Noise filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min Display: Max / min temperature readings are stored until reset by the user or until power to the meter is cycled.
Password: Three programmable passwords restrict modification of programmed settings. Pass 1: Allows use of function keys and digital inputs. Pass 2: Allows use of function keys, digital inputs and editing set/reset points. Pass 3: Restricts all programming, function keys, and digital inputs.
Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC 20 W max, or jumper selectable 12/24 VDC ±10%, 15 W max.
Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
Normal Mode Rejection: Greater than 65 dB at 50/60 Hz
Isolation: 4 kV input/output-to-power line. 500 V input-to-output
Environmental: Operating temperature range: -20 to 65°C. Storage temperature range: -40 to 85°C. Relative humidity: 0 to 90% non-condensing.
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Weight: 9.5 oz (269 g)
UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment.
Warranty: 3 years parts & labor
Temperature Input
Inputs: Thermocouple J, K, T, E, R, S, B, N, C; RTD 100 Ω platinum (0.00385 & 0.00392 curves), 10 Ω copper, 120 Ω nickel, 1000 Ω platinum
Input Impedance: Greater than 100 k Ω
Offset Adjust: User programmable offset adjust ±50.0 degrees
Temperature Drift: ±2°C maximum from 0 to 65°C ambient temperature; ±4°C maximum from -20 to 0°C ambient temperature
Sensor Break: Display flashes "Open", relays can be programmed to go "On", "Off", or to "Ignore" (detected as an upscale condition).
Averaging: Up to 10 RTDs connected in parallel can be averaged.
Accuracy & Range: See table below.
Type | Range (°F) | Range (°C) | Accuracy |
J | -200 to 2000 | -129 to 1093 | ±1°C |
K | -200 to 2400 | -129 to 1316 | ±1°C |
T | -200 to 752 | -129 to 400 | ±1°C |
E | -200 to 1800 | -129 to 982 | ±1°C |
R | -50 to 3000 | -46 to 1649 | ±2°C |
S | -50 to 3000 | -46 to 1649 | ±2°C |
B | 752 to 3300 | 400 to 1816 | ±2°C |
N | -100 to 2300 | -73 to 1260 | ±2°C |
C | 32 to 4100 | 0 to 2260 | ±2°C |
10 Ω | -328 to 500 | -200 to 260 | ±0.1°C |
100 Ω | -328 to 1562 | -200 to 850 | ±0.4°C |
120 Ω | -110 to 500 | -79 to 260 | ±0.1°C |
1000 Ω | -328 to 900 | -200 to 482 | ±0.4°C |
Relays
Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.
Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads.
Deadband: 0-100% of span, user programmable
High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off).
Relay Operation: Automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).
Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay.
Fail-Safe Operation: Programmable and independent for each relay.
Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state.
Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.
Isolated 4-20 mA Transmitter Output
Output Source: PV (temperature), max, min, set points 1-8, manual control setting, or Modbus input
Scaling Range: 1.000 to 23.000 mA for any display range
Calibration: Factory calibrated 4-20 mA output
Accuracy: ± 0.1% of span ± 0.004 mA
Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
Note: Analog output drift is separate from input drift.
Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10% @ 40 mA maximum, may be used to power the 4-20 mA output or other devices. Present on both AC & DC powered units.
External Loop Power Supply: 35 VDC maximum
Output Loop Resistance:
Power supply | Minimum | Maximum |
24 VDC | 10 Ω | 700 Ω |
35 VDC (external) | 100 Ω | 1200 Ω |
Serial Communications
Protocol: Modbus® RTU
Meter Address/Slave ID: 1 - 247
Baud Rate: 300 - 19,200 bps
Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication
Data: 8 bit (1 start bit, 1 or 2 stop bits)
Parity: Even, odd, or none with 1 or 2 stop bits
Byte-to-Byte Timeout: 0.01 - 2.54 seconds
Turn Around Delay: Less than 2 ms (fixed)
Note: Refer to the PD6000/PD7000 Modbus Register Tables for details, available in Documentation
Digital I/O Expansion Module
Channels: 4 digital inputs & 4 digital outputs per module
System: Up to 2 modules for a total of 8 inputs & 8 outputs
Digital Input Logic: High: 3 to 5 VDC Low: 0 to 1.25 VDC
Digital Output Logic: High: 3.1 to 3.3 VDC Low: 0 to 0.4 VDC
Source Current: 10 mA maximum
Sink Current: 1.5 mA minimum
+5 V Terminal: To be used as pull-up for digital inputs only.
4-Relay Expansion Module
Relays: Four Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads.
ORDERING INFORMATION
Products
ProVu PD7000: Standard Display Models |
|||||||
Model | Description | ||||||
PD7000-6R0 | ProVu Dual-Line 6-Digit Temperature Meter; No Options Installed; Powered from 85-265 VAC | ||||||
PD7000-6R2 | ProVu Dual-Line 6-Digit Temperature Meter; 2 Relays; Powered from 85-265 VAC | ||||||
PD7000-6R3 | ProVu Dual-Line 6-Digit Temperature Meter; 4-20 mA Output; Powered from 85-265 VAC | ||||||
PD7000-6R4 | ProVu Dual-Line 6-Digit Temperature Meter; 4 Relays; Powered from 85-265 VAC | ||||||
PD7000-6R5 | ProVu Dual-Line 6-Digit Temperature Meter; 2 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
PD7000-6R7 | ProVu Dual-Line 6-Digit Temperature Meter; 4 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
PD7000-7R0 | ProVu Dual-Line 6-Digit Temperature Meter; No Options; Powered from 12-24 VDC | ||||||
PD7000-7R2 | ProVu Dual-Line 6-Digit Temperature Meter; 2 Relays; Powered from 12-24 VDC | ||||||
PD7000-7R3 | ProVu Dual-Line 6-Digit Temperature Meter; 4-20 mA Output; Powered from 12-24 VDC | ||||||
PD7000-7R4 | ProVu Dual-Line 6-Digit Temperature Meter; 4 Relays; Powered from 12-24 VDC | ||||||
PD7000-7R5 | ProVu Dual-Line 6-Digit Temperature Meter; 2 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
PD7000-7R7 | ProVu Dual-Line 6-Digit Temperature Meter; 4 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
ProVu PD7000: SunBright Display Models |
|||||||
Model | Description | ||||||
PD7000-6H0 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; No Options Installed; Powered from 85-265 VAC | ||||||
PD7000-6H2 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 2 Relays; Powered from 85-265 VAC | ||||||
PD7000-6H3 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 4-20 mA Output; Powered from 85-265 VAC | ||||||
PD7000-6H4 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 4 Relays; Powered from 85-265 VAC | ||||||
PD7000-6H5 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 2 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
PD7000-6H7 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 4 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
PD7000-7H0 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; No Options; Powered from 12-24 VDC | ||||||
PD7000-7H2 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 2 Relays; Powered from 12-24 VDC | ||||||
PD7000-7H3 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 4-20 mA Output; Powered from 12-24 VDC | ||||||
PD7000-7H4 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 4 Relays; Powered from 12-24 VDC | ||||||
PD7000-7H5 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 2 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
PD7000-7H7 | ProVu SunBright Display Dual-Line 6-Digit Temperature Meter; 4 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
Enclosures |
|||||||
|
|||||||
Model | Description | ||||||
PDA2302 | Economical Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters | ||||||
PDA2303 | Economical Plastic NEMA 4X Enclosure for 3 Type A, B, C, or E Meters | ||||||
PDA2304 | Economical Plastic NEMA 4X Enclosure for 4 Type A, B, C, or E Meters | ||||||
PDA2305 | Economical Plastic NEMA 4X Enclosure for 5 Type A, B, C, or E Meters | ||||||
PDA2306 | Economical Plastic NEMA 4X Enclosure for 6 Type A, B, C, or E Meters | ||||||
PDA2307 | Economical Plastic NEMA 4X Enclosure for 7 Type A, B, C, or E Meters | ||||||
PDA2308 | Economical Plastic NEMA 4X Enclosure for 8 Type A, B, C, or E Meters | ||||||
PDA2309 | Economical Plastic NEMA 4X Enclosure for 9 Type A, B, C, or E Meters | ||||||
PDA2310 | Economical Plastic NEMA 4X Enclosure for 10 Type A, B, C, or E Meters | ||||||
PDA2312 | Economical Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters | ||||||
PDA2322 | Economical Plastic NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
PDA2407 | Plastic NEMA 4X Enclosure for 1 Meter (Any Type) | ||||||
PDA2411 | Plastic NEMA 4X Enclosure for 2 Meter (Any Type) | ||||||
PDA2414 | Plastic NEMA 4X Enclosure for 1 Type D + 1 Type A, B, C or E Meter | ||||||
PDA2504 | Plastic NEMA 4X Enclosure for 4 Type A, B, C, or E Meters | ||||||
PDA2505 | Plastic NEMA 4X Enclosure for 5 Type A, B, C, or E Meters | ||||||
PDA2506 | Plastic NEMA 4X Enclosure for 6 Type A, B, C, or E Meters | ||||||
PDA2507 | Plastic NEMA 4X Enclosure for 7 Type A, B, C, or E Meters | ||||||
PDA2508 | Plastic NEMA 4X Enclosure for 8 Type A, B, C, or E Meters | ||||||
PDA2509 | Plastic NEMA 4X Enclosure for 9 Type A, B, C, or E Meters | ||||||
PDA2510 | Plastic NEMA 4X Enclosure for 10 Type A, B, C, or E Meters | ||||||
PDA2512 | Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters | ||||||
PDA2522 | Plastic NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
PDA2604 | Stainless Steel NEMA 4X Enclosure for 4 Type A,B, C or E Meters | ||||||
PDA2605 | Stainless Steel NEMA 4X Enclosure for 5 Type A,B, C or E Meters | ||||||
PDA2606 | Stainless Steel NEMA 4X Enclosure for 6 Type A,B, C or E Meters | ||||||
PDA2622 | Stainless Steel NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
PDA2704 | Steel NEMA 4 Enclosure for 4 Type A, B, C, or E Meters | ||||||
PDA2705 | Steel NEMA 4 Enclosure for 4 Type A, B, C or E Meters | ||||||
PDA2706 | Steel NEMA 4 Enclosure for 5 Type A, B, C or E Meters | ||||||
PDA2722 | Steel NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
PDA2811 | Low-Cost Plastic NEMA 4X Enclosure for 1 Meter (Type A, B, C or E) | ||||||
PDA2812 | Low-Cost Plastic NEMA 4X Enclosure for 2 Meters (Any type) | ||||||
PDA2821 | Low-Cost Plastic NEMA 4X Enclosure for 1 Type D Meter + 1 Type A, B, C or E Meter | ||||||
Accessories |
|||||||
Model | Description | ||||||
PDA1002 | ProVu DIN Rail Mounting Kit for Two Modules | ||||||
PDA1004 | ProVu 4 Relays Expansion Module | ||||||
PDA1044 | ProVu 4 Digital Inputs & 4 Outputs Module | ||||||
PDA1200 | ProVu Meter Copy Cable, 3' (0.9 m) | ||||||
PDA1232 | ProVu RS-232 Serial Adapter | ||||||
PDA1485 | ProVu RS-422/485 Serial Adapter | ||||||
PDA7485-I | RS-232 to RS-422/485 Isolated Converter | ||||||
PDA7485-N | RS-232 to RS-422/485 Non-Isolated Converter | ||||||
PDA8232-N | USB to RS-232 Converter | ||||||
PDA8485-I | USB to RS-422/485 Isolated Converter | ||||||
PDA8485-N | USB to RS-422/485 Non-Isolated Converter | ||||||
PDA9485-01 | Ethernet Serial Server | ||||||
PDX6901 | Suppressor (snubber): 0.01µF/470Ω, |