产品详情
  • 产品名称:PD6000双行显示数显表

  • 产品型号:PD6000
  • 产品厂商:PRECISION
  • 产品价格:0
  • 折扣价格:0
  • 产品文档:
你添加了1件商品 查看购物车
简单介绍:
The PD6000 digital panel meter is a full-featured, high end, digital process meter that represents the continuum of 34 years of development by Precision Digital Corporation. The most noticeable featur
详情介绍:

Feature Rich and Flexible

The ProVu® digital panel meter boasts specifications and functionality that clearly make it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced math functions, function keys, Modbus RTU serial communications, and optional expansion modules are only a few of the features found on the ProVu PD6000.


FRONT PANEL DISPLAY

Precise, Accurate, and More Informative

ProVu's large 0.6" upper display provides a highly accurate and precise 6-digit view of the process measurement. Its 24-bit A/D is accurate to ± 0.03% of calibrated span ±1 count.

Configurable

The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/minimum, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off.


Optional SunBright Display Models

ProVu's SunBright display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. There are 8 user selectable intensity levels to choose from on all ProVu models. This option is available on all ProVu models.


PD6000 ProVu Dual Line 6 digit process meter Function Keys

Function Keys

There are three function keys available to the user. These keys can be programmed to trigger certain events (i.e. acknowledge alarms, reset max and/or min, disable/enable output relays, or hold current relay states), provide direct menu access points, and more.

Learn more about using the ProVu's Function Keys by watching a video click here to watch.


 
PD6000 Dual Line 6 digit process meter Front Panel Display Rugged

Rugged

A unique front panel design makes the ProVu digital panel meter nearly impenetrable in typical applications. Here, the ProVu easily survives a direct hit on the display from a heavy 2" solid stainless steel ball dropped from eight feet.


 
Input and display setup

Easy to Use

The user friendly dual-line display makes the ProVu easy to set up
& program. No jumpers to set for input selection. All setup & programming is done via the front panel. Three levels of password protection help maintain the reliability of the programming.



Dual-Scale Display Feature

The ProVu PD6000 has a rather unique and very flexible dual-scale capability; a second scaled display can represent the measured input in a different form (i.e. gallons & height). This is of particular value in level applications. Please see the examples shown below. Both displays are independently scaled and are based on the 4-20 mA input signal. Beyond level, this function has been used for pressure & force, current & power, feet & meters, GPM & CFM, and more.

 
Gallons and mA
Gallons and mA
 
Gallons and Height
Gallons and Height
 
Gallons and Percent
Gallons and Percent
Gallons and Head PSI
Gallons and Head PSI


Three Tier Password Protection

The ProVu offers 3 levels of password protection:
  • Level 1 protection allows the operator use of only the 3 pre-configured function keys on the front panel without a password.
     
  • Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password.
     
  • Level 3 protection restricts the operator from using the function keys and all meter configuration menus without a password.
     

Advanced Linearization Capability

The ProVu includes a 32-point linearizer. In non-linear level applications (i.e. some pumping or lift stations), it can easily compensate for submerged equipment or plumbing that displace usable volume. A second independent 8-point linearizer is available for a second scaled display (PV2) when "Level" function is enabled. Precision Digital's free MeterView Pro PC-based software greatly simplifies the construction of the linearization tables. The software can save this data to the meter and/or PC.


Simplified & Dynamic Menu System

The ProVu minimizes the menu selections by auto-detecting the installed options to determine what menu navigation is required. For example, extra menu items for the relay expansion module, I/O expansion, etc. are not present unless those options have been installed. This is an example of keeping the product simply sophisticated.


Max/Min Display

Max/Min (or Peak/Valley) is standard on the ProVu PD6000. Either display can be configured to show either maximum or minimum excursion since last reset. The displays can also be configured to toggle between Max and Min values. Both values can be simply reset from the front panel.


Environmentally Protected

The ProVu has standard UV protection, a NEMA 4X front panel, extremely durable face plate, performs in wide ambient operating temperatures, and is CE Certified (high noise and RF immunity).


DIGITAL COMMUNICATIONS

Modbus® RTU Serial Communications

After the purchase of a serial communication adapter for the ProVu meter, any Modbus-ready Master device can communicate with the meter using the ever-popular Modbus communications protocol included in every ProVu. This greatly increases the flexibility of the meter. Modbus provides much more capability than read PV and write set points. Below are some examples of other things that can be done with ProVu's Modbus communications. Modbus PV Input and Remote message
  • Send a 6-character message to the lower display upon an event
  • Convert a digital value to a 4-20 mA signal
  • Remote user control (i.e. change set points, acknowledge alarms)
  • Input a Modbus digital PV (in place of analog input)
  • Remote override of any, or all, relays and analog outputs


Meter Copy

The Copy feature is used to copy (or clone) all the settings from one ProVu to other ProVu meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adapter, only an optional cable assembly, P/N PDA1200. See the ordering information for complete details.

PD6000 dual-line 6 digit process meter Meter Copy



View the ProVu Video
Click here to see the
ProVu videos

ProVu VIDEOS

Watch a quick demonstration on how the ProVu works and also how the function keys can simplify functionality. These and other videos are available click here.



 

FIELD EXPANSION MODULES

Add functionality to the ProVu in the field with easy-to-install external expansion modules. Add RS-232 or RS-422/485 communications, I/O modules (up to 2), or 4-relay expansion module. The menu items for these modules do not appear until the module is connected, simplifying the basic menu. Relay and digital I/O modules are shown below with optional DIN rail mounting kit, P/N PDA1002.

PD6000 Provu dual-line 6 digit process meter Field Expandable options



PDA1044 I/O Expansion Module

Four digital inputs and four digital outputs are available per expansion module. The ProVu meter will accept two of these modules. External digital inputs can function similarly to the front panel function keys. They can be configured to trigger certain events (i.e. acknowledge/reset alarms, reset max and/or min values, disable/enable all output relays, and hold current relay states), provide direct menu access point, or mimic front panel keys. The I/O module can be used to configure the ProVu remotely, in essence giving the user control of the four front panel push buttons. This feature is particularly useful if the meter is mounted inside an explosion-proof enclosure.

Digital outputs can be used to remotely monitor ProVu's alarm relay output states, or the states of a variety of actions and functions executed by the meter.

PDA1004 Relay Expansion Module

An external module containing four 3 A Form A (SPST) relays can be added to the ProVu at anytime.

Removable screw terminal blocks accept 12 to 22 AWG wire.
PD6000 Relay Expansion module
pd6000 dual-line 6 digit process meter communications module

PDA1232 & PDA1485 Communication Modules

Serial communications on the ProVu can be added anytime with external PDA1232 (RS-232) or PDA1485 (RS-422/485) communication adapters.
 



METERVIEW® PRO SOFTWARE

View the ProVu Video
Click here to see the
ProVu videos
Configure, monitor, or datalog any ProVu series meter using the PC-based MeterView Pro (MVP) software (serial communications adapter required). MVP makes complete meter configuration simple and fast. Copying one meter configuration to another, as well as saving or retrieving a meter configuration file is a snap. MVP's linearization utility makes even a 32-point linearization task clear and easy to do. We also included a basic meter monitor and data logger for use with a ProVu. Of course, with ProVu's powerful Modbus protocol, custom programs can be made even more versatile. For more details on MeterView Pro, click here.


Monitoring and Datalog

Monitor and Datalog

Setup

Setup

Setup

Programming

Relays

Relays



OUTPUTS

Relay Outputs

The ProVu has up to four 3 A Form C relays (SPDT) with multiple power loss fail-safe options. Relays can be configured for proper protective action upon input loop break. Relay ON and OFF delay times are user adjustable. Up to eight front panel indicators show alarm and/or relay state. All relays can be configured for 0-100% deadband. PD6000 dual-line process meter relay outputs

 


Relay Operation/Configuration

There are powerful relay functions that can be configured in the ProVu meter, including:

  • Automatic reset only (non-latching)
  • Automatic + manual reset at any time (non-latching)
  • Latching (manual reset only)
  • Latching with Clear (manual reset only after alarm condition has cleared)
  • Pump alternation control (automatic reset only)
  • Sampling (activated for a user-specified time)
  • User selectable fail-safe operation
  • Relay action for loss (break) of 4-20 mA input signal
  • Time delay (on and off), independent for each relay
  • Manual control mode
  • Interlock relay mode

Analog Output

The isolated analog retransmission signal can be configured to represent the process variable (PV), maximum (peak) value, minimum (valley) value, the value for any of the eight relay set points, or Modbus input. While the output is nominally 4-20 mA, the signal will accurately accommodate under- and over-ranges from 1 to 23 mA.


 Auto/Manual Control

Auto/Manual Control

Take control of any output with this feature. All relays can be forced ON or OFF, and the 4-20 mA output signal can be set to any value within its range. When the relays and 4-20 mA output are controlled manually, an LED labeled "M" is turned on and the associated Alarm LEDs (1-8) flash every 10 seconds indicating that the meter is in manual control mode.


Isolated Transmitter Power Supplies

A powerful 24 V @ 200 mA power supply is a standard feature on the ProVu meter. It can be configured for 5, 10, or 24 V (default) by means of a simple internal jumper (see manual). An additional power supply (24 V @ 40 mA) is standard with the 4-20 mA output option.


Sampling Function (PV Triggered Timed Relay)

The sampling function allows the operator to set a set point for a "sampling" relay. When the PV reaches that set point, it will close that relay's contacts for a preset period of time (0.1 to 5999.9 seconds). An example of its use may be for beer/ale fermentation. When the batch reaches a certain pH, the relay contacts would close and by some means (light, horn, etc.) alert someone to take a sample, or provide the trigger to automatically take a sample of the batch. The utility of this function can, of course, be expanded beyond sampling and be used whenever a timed relay output closure is required when the PV reaches a certain set point.


Interlocking Relays

Interlock Relay(s)

This function allows a process to use one or more very low voltage input signals or simple switch contacts to control the state of one or more internal "interlock" relays. A violation (i.e. loss of input, open switch, or open circuit) forces one or more N/O interlock relay contacts to open. One input can be used in series with a number of interlock switches, or up to eight inputs can be required to force-on one (or more) internal interlock relays. Please see Application Note AN-1008 for more information.


Note: Requires PDA1044 Digital I/O module.


MATH FUNCTIONS

Non-linear input signals (i.e. weirs & flumes, differential pressure, etc.) can be linearized with the ProVu's simple to use built-in math functions, such as: square-root extractor, exponential linearizer, horizontal round tank linearizer, or the ProVu's powerful general purpose 32-point linearizer.

Weir Flow Calculated Using Exponential Math Function

 
PD6000 dual-line 6 digit process meter math functions

 
Round Horizontal Tank Math Function

 
PD6000 dual-line 6 digit process meter Math Functions

 



View the ProVu Video
Click here to see the
Multi-pump alternation video

Multi-Pump Alternation

For pump control applications where 2 or more similar pumps are used to control the level of a tank or a well, it is desirable to have the pumps operate alternately; this prevents excessive wear and overheating of one pump over the lack of use of the others. The ProVu can accommodate up to 8 pumps. In the example below, a pair of relays have been set up to alternate every time an on/off pump cycle is completed. Another pair of relays is used for low and high alarms.


PD6000 dual-line process meter 6 digit multi-pump alternation 1
Relay #4 turns the main pump on at 6000 gallons and turns it off at 1000 gallons.


PD6000 dual-line 6 digit process meter Multi-pump alternation 2
With the Pump Alternation feature activated, the next time the level reaches 6000 gallons, relay #3 transfers and starts the backup pump.


pd6000 6 digit process meter multi line alternation 3
If the backup pump is not able to keep up, and the level reaches 7000 gallons, relay #4 transfers and starts the main pump as well.


pd6000 dual-line process meter multi-line alternation 4
Relay #2 trips the High Level Alarm at 7500 gallons and resets at 6900 gallons.


pd6000 dual-line 6 digit process meter multi-pump alternation 5
Relay #1 trips the Low Level Alarm at 495 gallons and resets at 750 gallons.



NEMA 4 & 4X FIELD ENCLOSURES

Plastic, stainless steel, and painted steel NEMA 4 enclosures for up to 10 ProVu meters.

 
Enclosure Selection Utility
Enter the Enclosure Selection Utility


 
PD6000 dual-line 6 digit process meter NEMA 4 and 4X field enclosure

CONNECTIONS

PD6000 dual-line 6 digit process meter connections

 

SPECIFICATIONS

Except where noted all specifications apply to operation at +25°C

General

Display: Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking.
Display Intensity: Eight intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper & lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), and Modbus input.
Front Panel: NEMA 4X, IP65
Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers, or cloning using Copy function.
Noise filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak) / min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: Three programmable passwords restrict modification of programmed settings. Pass 1: Allows use of function keys and digital inputs. Pass 2: Allows use of function keys, digital inputs and editing set/reset points. Pass 3: Restricts all programming, function keys, and digital inputs.
Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost
Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC 20 W max or jumper selectable 12/24 VDC ±10%, 15W max.
Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply: Terminals P+ ∓ P-: 24 VDC ±5% @ 200 mA max (standard), (12/24 VDC powered models rated @ 100 mA max). 5 or 10 VDC @ 50 mA max, selectable with internal jumper J4.
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply
Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Operating Temperature Range: -40 to 65°C
Storage Temperature Range: -40 to 85°C
Relative Humidity: 0 to 90% non-condensing.
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Weight: 9.5 oz (269 g)
UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment
Warranty: 3 years parts & labor



Process Input

Inputs: Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (slave)
Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span
Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient
Math Function: Linear, square root, programmable exponent, or round horizontal tank volume calculation
Multi-Point Linearization: 2 to 32 points for PV or PV1. 2 to 8 points for PV2 (Dual-Scale Level feature)
Programmable Exponent: 1.0001 to 2.9999
Low-Flow Cutoff: 0-999999 (0 disables cutoff function)
Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd
Calibration Range: 4-20 mA: minimum span input 1 & input 2: 0.15 mA. ±10 V: minimum span input 1 & 2: 0.10 V. An Error message will appear if input 1 and input 2 signals are too close together.
Input Impedance: Voltage ranges: greater than 1 MΩ. Current ranges: 50 - 100 Ω (depending on resettable fuse impedance)
Input Overload: Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed



Relays

Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.
Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads
Deadband: 0-100% of span, user programmable
High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off)
Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).
Relay Reset: User selectable via front panel buttons or digital inputs
  1. Automatic reset only (non-latching), when input passes the reset point
  2. Automatic + manual reset at any time (non-latching)
  3. Manual reset only, at any time (latching)
  4. Manual reset only after alarm condition has cleared (latching)
Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset
Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay
Fail-Safe Operation: Programmable and independent for each relay
Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state
Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter


Serial Communications

Protocol: Modbus® RTU
Meter Address/Slave ID: 1 - 247
Baud Rate: 300 - 19,200 bps
Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication
Data: 8 bit (1 start bit, 1 or 2 stop bits)
Parity: Even, odd, or none with 1 or 2 stop bits
Byte-to-Byte Timeout: 0.01 - 2.54 seconds
Turn Around Delay: Less than 2 ms (fixed)
Note: Refer to the PD6000/PD7000 Modbus Register Tables for details


Isolated 4-20 mA Transmitter Output

Output Source: Process variable (PV), max, min, set points 1-8, manual control setting, or Modbus input
Scaling Range: 1.000 to 23.000 mA for any display range
Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
Analog Output Programming: 23.000 mA maximum for all parameters: Overrange, underrange, max, min, and break
Accuracy: ± 0.1% FS ±0.004 mA
Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
Note: Analog output drift is separate from input drift.
Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10% @ 40 mA maximum, may be used to power the 4-20 mA output or other devices. Present on both AC & DC powered units.
External Loop Power Supply: 35 VDC maximum
Output Loop Resistance:
Power supply Minimum Maximum
24 VDC 10Ω 700Ω
35 VDC (external) 100Ω 1200Ω



Digital I/O Expansion Module

Channels: 4 digital inputs & 4 digital outputs per module
System: Up to 2 modules for a total of 8 inputs & 8 outputs
Digital Input Logic: High: 3 to 5 VDC Low: 0 to 1.25 VDC
Digital Output Logic: High: 3.1 to 3.3 VDC Low: 0 to 0.4 VDC
Source Current: 10 mA maximum
Sink Current: 1.5 mA minimum
+5 V Terminal: To be used as pull-up for digital inputs only


4-Relay Expansion Module

Relays: (4) Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads


MOUNTING DIMENSIONS

PD6000 dual-line 6 digit process meter mounting dimensions

 
Notes:
1. Panel cutout required: 1.772" x 3.622" (45mm x 92mm)
2. Panel thickness: 0.040 - 0.250" (1.0mm - 6.4mm)
3. Mounting brackets lock in place for easy mounting
4. Clearance: Allow 6" (152 mm) behind the panel.


ORDERING INFORMATION

ProVu PD6000: Standard Display

Model Description  

QuickShip Program Eligible ProductBlue dot denotes item as a Quick Ship product

 
PD6000-6R0 QuickShip Program Eligible Product        ProVu Dual-Line 6-Digit Process Meter; No Options Installed; Powered from 85-265 VAC         
PD6000-6R2 QuickShip Program Eligible Product        ProVu Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 85-265 VAC         
PD6000-6R3 QuickShip Program Eligible Product        ProVu Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 85-265 VAC         
PD6000-6R4 QuickShip Program Eligible Product        ProVu Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 85-265 VAC         
PD6000-6R5 QuickShip Program Eligible Product        ProVu Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 85-265 VAC         
PD6000-6R7 QuickShip Program Eligible Product        ProVu Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 85-265 VAC         
PD6000-7R0        ProVu Dual-Line 6-Digit Process Meter; No Options; Powered from 12-24 VDC         
PD6000-7R2        ProVu Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 12-24 VDC         
PD6000-7R3        ProVu Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 12-24 VDC         
PD6000-7R4        ProVu Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 12-24 VDC         
PD6000-7R5        ProVu Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 12-24 VDC         
PD6000-7R7        ProVu Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 12-24 VDC         

ProVu PD6000: SunBright Display

Model Description  
PD6000-6H0 QuickShip Program Eligible Product        ProVu SunBright Display Dual-Line 6-Digit Process Meter; No Options Installed; Powered from 85-265 VAC         
PD6000-6H2 QuickShip Program Eligible Product        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 85-265 VAC         
PD6000-6H3 QuickShip Program Eligible Product        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 85-265 VAC         
PD6000-6H4 QuickShip Program Eligible Product        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 85-265 VAC         
PD6000-6H5 QuickShip Program Eligible Product        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 85-265 VAC         
PD6000-6H7 QuickShip Program Eligible Product        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 85-265 VAC         
PD6000-7H0        ProVu SunBright Display Dual-Line 6-Digit Process Meter; No Options; Powered from 12-24 VDC         
PD6000-7H2        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 12-24 VDC         
PD6000-7H3        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 12-24 VDC         
PD6000-7H4        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 12-24 VDC         
PD6000-7H5        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 12-24 VDC         
PD6000-7H7        ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 12-24 VDC         
 

Enclosures

Thermoplastic and stainless steel NEMA 4X, and painted steel NEMA 4 enclosures for up to 10 ProVu meters are available. Please visit our Enclosure Selection Utility at www.predig.com/esu for an easy way to find the right enclosure.

PDA2300 Enclosure Family



Enclosure Selection Utility
Enter the Enclosure Selection Utility
Model Description  
PDA2302        Economical Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters         
PDA2303        Economical Plastic NEMA 4X Enclosure for 3 Type A, B, C, or E Meters         
PDA2304        Economical Plastic NEMA 4X Enclosure for 4 Type A, B, C, or E Meters         
PDA2305        Economical Plastic NEMA 4X Enclosure for 5 Type A, B, C, or E Meters         
PDA2306        Economical Plastic NEMA 4X Enclosure for 6 Type A, B, C, or E Meters         
PDA2307        Economical Plastic NEMA 4X Enclosure for 7 Type A, B, C, or E Meters         
PDA2308        Economical Plastic NEMA 4X Enclosure for 8 Type A, B, C, or E Meters         
PDA2309        Economical Plastic NEMA 4X Enclosure for 9 Type A, B, C, or E Meters         
PDA2310        Economical Plastic NEMA 4X Enclosure for 10 Type A, B, C, or E Meters         
PDA2312        Economical Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters         
PDA2322        Economical Plastic NEMA 4X Enclosure for 1 Type D + 1 Type C Meter         
PDA2407        Plastic NEMA 4X Enclosure for 1 Meter (Any Type)         
PDA2411        Plastic NEMA 4X Enclosure for 2 Meter (Any Type)         
PDA2414        Plastic NEMA 4X Enclosure for 1 Type D + 1 Type A, B, C or E Meter         
PDA2504        Plastic NEMA 4X Enclosure for 4 Type A, B, C, or E Meters         
PDA2505        Plastic NEMA 4X Enclosure for 5 Type A, B, C, or E Meters         
PDA2506        Plastic NEMA 4X Enclosure for 6 Type A, B, C, or E Meters         
PDA2507        Plastic NEMA 4X Enclosure for 7 Type A, B, C, or E Meters         
PDA2508        Plastic NEMA 4X Enclosure for 8 Type A, B, C, or E Meters         
PDA2509        Plastic NEMA 4X Enclosure for 9 Type A, B, C, or E Meters         
PDA2510        Plastic NEMA 4X Enclosure for 10 Type A, B, C, or E Meters         
PDA2512        Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters         
PDA2522        Plastic NEMA 4X Enclosure for 1 Type D + 1 Type C Meter         
PDA2604        Stainless Steel NEMA 4X Enclosure for 4 Type A,B, C or E Meters         
PDA2605        Stainless Steel NEMA 4X Enclosure for 5 Type A,B, C or E Meters         
PDA2606        Stainless Steel NEMA 4X Enclosure for 6 Type A,B, C or E Meters         
PDA2622        Stainless Steel NEMA 4X Enclosure for 1 Type D + 1 Type C Meter         
PDA2704        Steel NEMA 4 Enclosure for 4 Type A, B, C, or E Meters         
PDA2705        Steel NEMA 4 Enclosure for 4 Type A, B, C or E Meters         
PDA2706        Steel NEMA 4 Enclosure for 5 Type A, B, C or E Meters         
PDA2722        Steel NEMA 4X Enclosure for 1 Type D + 1 Type C Meter         
PDA2811        Low-Cost Plastic NEMA 4X Enclosure for 1 Meter (Type A, B, C or E)         
PDA2812        Low-Cost Plastic NEMA 4X Enclosure for 2 Meters (Any type)         
PDA2821        Low-Cost Plastic NEMA 4X Enclosure for 1 Type D Meter + 1 Type A, B, C or E Meter         
  

Accessories

Model Description  
 PDA1002        ProVu DIN Rail Mounting Kit for Two Modules         
 PDA1004        ProVu 4 Relays Expansion Module         
 PDA1044        ProVu 4 Digital Inputs & 4 Outputs Module         
 PDA1200        ProVu Meter Copy Cable, 3' (0.9 m)         
 PDA1232        ProVu RS-232 Serial Adapter         
 PDA1485        ProVu RS-422/485 Serial Adapter         
 PDA7485-I        RS-232 to RS-422/485 Isolated Converter         
 PDA7485-N        RS-232 to RS-422/485 Non-Isolated Converter         
 PDA8232-N        USB to RS-232 Converter         
 PDA8485-I        USB to RS-422/485 Isolated Converter         
 PDA8485-N        USB to RS-422/485 Non-Isolated Converter         
 PDA9485-01        Ethernet Serial Server         
 PDX6901        Suppressor (snubber): 0.01µF/470Ω,         